English          
Industrial Measurement & Control, CEM systems, measuring vans, shelter, analysers and gasconditiongcomponents
Laboratory equipment, color-, ph-, ion selective-, polari-, refracometers
Farmer measurements, NH3, emmision
Reduced Oxygen Reduced Breathing Device, Gas mixing systems
Refractometers, Color measurements and Calcium
Service, Preventive and corrective maintenance, 24/7 contracts
Marine emission monitoring
Home > Producten > Gas analyzers > NDIR gas analysers > Multi-Gas Non-dispersive IR GFC Analyzer MIR 9000

Filter.

Type hieronder om het element te zoeken


Type meting










Show More

Meettechniek































Show More

Merk





























Show More

Industrie















Show More

Multi-Gas Non-dispersive IR GFC Analyzer MIR 9000

Biedt uitstekende prestaties voor multigasmetingen bij droge bemonstering, waaronder HCl, HF, NO, NO2, N2O, SO2, CO, CH4, TOC, CO2 en O2.Multi-Gas NDIR-GFC-analysator MIR 9000
Biedt uitstekende prestaties voor multigasmetingen bij droge bemonstering, waaronder HCl, HF, NO, NO2, N2O, SO2, CO, CH4, TOC, CO2 en O2.

Multi-Gas NDIR-GFC-analysator (Non-Dispersive Infrared Gas Filter Correlation) meet tot tien gassen tegelijk, waaronder stikstofoxide (NO), stikstofdioxide (NO2), zwaveldioxide (SO2), koolmonoxide (CO), zelfs waterstofchloride (HCl) en waterstoffluoride (HF).

Wereldwijd zijn er meer dan 4.000 MIR9000 gas-CEMS-monitoren geïnstalleerd voor procesoptimalisatie en naleving van milieuvoorschriften

Kenmerken en voordelen
  • De MIR 9000 is de populairste ENVEA extractieve multi-gasanalysator, die in alle soorten industrieën wordt gebruikt en voldoet aan alle regelgevingen wereldwijd
  • Ontworpen om droge en corrosieve monsters te meten
  • Snelle en gelijktijdige metingen van maximaal 10 gassen
  • Droge basismeting
  • Automatische kruisinterferentiecorrectie
  • Ideaal te gebruiken met SEC® box permeatie monsterdroogtechnologie en niet-verwarmde monsterleidingen voor kosteneffectieve bewerkingen
  • Intrinsieke beveiliging met rest-H2O-meting
  • Ingebouwde paramagnetische cel voor O2-bewaking
  • De MIR-9000 is verkrijgbaar in een 19″ rack of wandmontagebehuizing (Tight box-versie)
Belangrijkste toepassingen
  • Schoorsteenemissie-naleving voor gemeentelijke en gevaarlijke afvalverbrandingsinstallaties
  • Warmtekrachtkoppeling, gasturbines (voor ultra-lage NOx-metingen raden wij het gebruik van het model MIR 9000 CLD aan)
  • Industriële boilers en ovens
  • Stroom en verbranding
  • Cementovens, glas, chemische en petrochemische fabrieken
  • Efficiëntiecontrole voor DeNOx-systemen om hun juiste prestaties te garanderen
  • Voor pre- en post-katalysator SO2-bewaking (DeSOx-eenheidsprocescontrole) raden wij het gebruik van het model MIR 9000ASD aan
Measurable parameters
Pollutant Range
HCI 0-15 / 5000
HF 0-20 / 300
NO 0-100 / 5000
NO2 0-100 / 1000
N2O 0-20 / 1000
NOx 0-200 / 5000
SO2 0-75 / 5000
CO 0-75 / 1000
CH4 0-10 / 1000
THC 0-50 / 5000
CO2(%) 0-10 / 100
O2(%) 0-10 / 25
Lowest / Highest available ranges expressed in mg/m3 (may vary with your site conditions to be indicated on the Site Survey Form)
Other ranges available upon request
Technical Specifications
QAL1 to EN 15267-3 certified YES
US EPA compliance YES
Sampling technology Cold/Dry Extraction
Sample transfert non heated polytube
back flush function YES
span injection YES on analyser or at sample point
Built-In O2 option YES
Serial link communication RS232 / RS422
Other Communication Ethernet
Analogue OUTPUTS Optional
Analogue INPUTS Optional
Dimensions (mm) • Tight box version: 200 x 400 x 600 (D x W x H)
• 19” rack version: 490 x 483 x 177 (D x W x H)
Een compleet CEMS bestaat normaal gesproken uit:
  • MCERTS & TÜV QAL 1 gecertificeerde MIR-9000 multi-gas emissie-analysator
  • Grafiet 52M FID (indien gewerkt volgens EN12619 VOC-norm)
  • Monsterextractie- en conditioneringsonde (met of zonder geïntegreerde temperatuur-, druk- en stroommeting)
  • SEC® bemonsteringssysteem (permeatiegebaseerd) of gaskoeler
  • Monsterleidingen
  • Automatische kalibratie-eenheden (TIG)
  • Instrumentenluchtdroogsysteem (MDS)
  • Multiplexsysteem (MVS) voor dubbele redundantie*
  • Rackkast-, cubicle- of shelterintegratie
  • MCERTs gecertificeerd ENVEA WEX Data-acquisitie- en beheersysteem
*Dual Redundancy System
Onder de IED mag de maximaal toegestane periode voor één enkele episode van vermindering of apparatuurstoring niet langer zijn dan vier uur. Bovendien mag de totale toegestane periode voor een jaar niet langer zijn dan zestig uur.

De ENVEA duplexfilosofie is daarom speciaal ontwikkeld om u te helpen voldoen aan de IED door de uitvaltijd te beperken, de beschikbaarheid te maximaliseren en ervoor te zorgen dat u een goed rendement op uw investering behaalt.

Goedkeuringen en certificeringen
  • The MIR 9000 multi-gas CEMS offer compliance with EU Regulation IED (WID / LCPD / MCP directive) BREF Incineration, US EPA (40 CFR 60 & 75)
  • QAL 1 certified by the TÜV and the MCERTs to EN 15267
  • 0000024158 MCERTs QAL 1 certified gas monitorSira MC020010/13
  • QAL3 compliance as defined by EN 14181
  • U.S. EPA approved as compliant with 40 CFR 60 ET 75

Documentatie

ENVEA_MIR_9000_emission-process-multi_gas_ir_gfc_analyzer_EN ENVEA_MIR_9000_emission-process-multi_gas_ir_gfc_analyzer_EN
envea_catalogue_cems_emission-monitoring_en envea_catalogue_cems_emission-monitoring_en

Ankersmid engineert, levert en pleegt service aan analyse apparatuur, tot complete CEM systemen en proces systemen in bijbehorende analysehuizen. Zij worden gebruikt in de industriële procestechniek, laboratoria, luchtmacht, staltechnieken en biogas installaties

Ankersmid Process
Samuel Morsestraat 4
7442 DH Nijverdal
Netherlands


(31)-0548-59 59 69
(31)-0548-62 19 72
info@ankersmid.com

© 2024 - Ankersmid Group